Gauge¶
The display shows a process value in the form of a gauge display.
Parameters
base – Address used for output and status monitoring.
alarm address – Optional address used for alarm monitoring.
enable status monitoring – Switch monitoring of current value status on or off (default: Yes).
fire status trigger – Instead of the status display a here defined trigger can be fired globally.
unit – This unit is displayed in addition to the value.
decimal places – Number of decimal places for the value to be displayed (default: 0).
minimum – Lower limits of the displayed values (default: 0).
maximum – Upper limit of the displayed values (default: 100).
Appearance:
deactivation color – Deactivation color (default: #b7b7b7)
text color – Text color (default: global parameter atvFontColor)
status indication – Specify the status' display through a defined global list (default: global parameter atvStatusIndication)
alarm indication – Specify the alarm's display through a defined global list (default: global parameter atvAlarmIndication)
bar color – Defines the bar color of the progress bar (default: #7cb5ec)
bar background color – Defines the bar background color of the progress bar (default: #eeeeee).
bar border color – Defines the bar contour color of the progress bar (default: #d7d7d7).
bar border width – Defines the bar contour size of the progress bar (default: 1).
Options:
address for minimum – Optional address for defining the lower limit.
address for maximum – Optional address for defining the upper limit.
Security:
necessary right – The user must have this right to activate this control.
activation address – If the value of this address equals to "activation value", then the control will be active.
activation value – Value which activates the control.
show access control notification – Defines if the icon for showing access control notifications shall be displayed (default: true)